ope体育news
24小时客服

021-63082088
021-39879018

首页〉产品中心〉产品中心

XLTR-40型变压器直流电阻测试仪

XLTR-40型变压器直流电阻测试仪

XLTR Series DC Resistance Tester

 

一、概述 General Introduction


During transformer manufacture, direct current (DC) resistance test is necessary during half-manufacture, out-of-factory, installation and acceptance procedure. Through the test, some problems or danger can be found concerning the material, welding, connection, strand and lines. To meet fast DC resistance test demand, our company developed XLTR series DC resistance tester. The equipment adopts new power technology, and features with small volume, small weight and large output current. The equipment is controlled by single plate device and automatically completes self-inspection, data procession and display. Also it has function of automatic discharge and discharge indication. The equipment has high precision and is easy to operate. Therefore, it realizes the fast measure of transformer DC resistance.

 

 

 

二、宁静措施 safety measure

1、使用本仪器前一定要认真阅读本手册。

Please read this manual before using the equipment

2、仪器的操纵者应具备一般电气设备或仪器的使用常识。

The operator shall be the one who is familiar with general electric eqipment knowledge.

3、本仪器户内外均可使用,但应避开雨淋、腐蚀气体、尘埃过浓、高温、阳光直射等场所使用。

The equipment can be used both indoors and outdoor. However, it is not used in conditions of rain, errosive gas, heavy dust, high temperature and strong sunshine.

4、仪表应制止剧烈振动。

The meter of the equipment shall avoid strong shake.

5、对仪器的维修、护理和调整应由专业人员进行。

The manitenance, repairment and regulation shall be dealt with by experts.

6、测试完毕后一定要等放电报警声停止后再关闭电源,拆除测试线。

After tests, the power shall not be turned off until the electric warning sound finishes. Then remove the test lines.

7、丈量无载调压变压器,一定要等放电指示报警音停止后,切换档位。

To test no-load regulation transformer, the levels shall not be switched until the electric warning sound finishes.

8、在测试过程中,禁止移动测试夹和供电线路。

Test clamps or power supply circuit shall not be moved during the tests.

三、性能特点

1、仪器输出电流大,重量轻。

Large output current and small weight

2、具有完善的保护电路,可靠性强。

Perfect protection circuit with reliability

3、立式机箱结构,便于现场操纵。

Standing cabinet structure for easy operation on site

4、具有音响放电报警,放电指示清晰,减少误操纵。

With accoustic electicity warning, with obvious message to avoid error.

 

 

四、技术指标 technical standards

1、输出电流 output current:5A、10A、20A、40A

2、量程 measure range:50μΩ~0.5Ω   (40A)

           100μΩ~1Ω    (20A)

           200μΩ~2Ω    (10A)

3、准确度accuracy:0.2%

4、分辨率resolution:0.1μΩ

5、工作温度working temperature:0~40℃

6、环境湿度working humidity:≤90%RH,无结露with no dew condensation

7、工作电源working power :AC220V±10%,50Hz±1Hz